Powerflow Electrical/Electronic No Loss Drain

300-11-050

Type – NLD-50
Inlet – 1/2” x 2
Outlet – 1/2” x 1
Thread Type – BSP
Air Compressor Performance – 50m³/min
Order Ref. – 300-11-050

The Electronic No Loss Drain removes harmful condensate from receiver tanks, aftercoolers, dryers, filters and drip legs.

 

Features:

  • 100% Continuous duty
  • LED lights to indicate power is ON and to indicate valve is OPEN
  • Manual override switches
  • NEMA 4 (IP65) enclosure
  • 6 ft heavy duty power cord with AC plug – DIN
  • Bright power indicator
  • CE & TUV approved to UL standards
  • Brass body with stainless steel internals
  • Long lasting VITON seals
  • Maximum working pressure up to 250 PSI

Benefits:

  • Improves air system performance
  • Eliminates frequent downtime maintenance
  • Prevents corrosion and scaling
  • Increases the air-carrying capacity of the pipelines
  • Prevents freezing and bursting of pipelines in winter
  • Extends equipment life

Specification

Housing Protection

IP65

Type

NLD-50

Order Ref.

300-11-050

Air Compressor Performance (max)

50m³/min

Refrigerated Air Dryer Performance (max)

100m³/min

Filter Performance (max)

500m³/min

Short term peak load (from 7.0Bar)

192l/hr

Operating pressure (min/max)

0.8 – 16Bar

Temperature (min/max)

+1°C to +80°C* (down to -25°C with heating unit and proper insulation)

Condensate Inlet

½” x 2 BSP

Condensate Discharge

1/2” x 1 BSP

Weight

2.1kg

Application

Oil Free Compressor + Oil Injection Compressor

Power

Standard – 90 – 260VAC (Free Voltage) / 50-60Hz / 1P
Order Voltages – 24VAC.48VAC / 24VDC.48VDC

Material

Housing – Aluminium, Hardcoated
O-Ring – NBR
Diaphragm – NBR
Casing – PP

Extra Type

Heater

Heater Order Ref.

300-60-001
300-60-002

Operating Pressure with Heater (max)

25Bar

Temperature with Heater (min/max)

-25°C to +80°C

Request Callback
close